Railway Signals in Goyanes: Difference between revisions
20agoyanes (talk | contribs) |
20agoyanes (talk | contribs) (Added DRA and all signage) |
||
Line 241: | Line 241: | ||
The ATS-M system may be overridden (in case of a shunting signal allowing access) by holding down the override button as the train passes over the magnet. Mechanical ATS systems such as on the U-Baner cannot be overridden except by dispatch due to the nature of the system. | The ATS-M system may be overridden (in case of a shunting signal allowing access) by holding down the override button as the train passes over the magnet. Mechanical ATS systems such as on the U-Baner cannot be overridden except by dispatch due to the nature of the system. | ||
== Driver Reminding Apparatus (DRA) == | |||
[[File:DRAButton.jpg|thumb|right|A DRA console in the cab of a locomotive. The DRA has been set, as the button is illuminated.]] | |||
The DRA (Førermann Påminnelsemasjin/FPM) is a memory device used as an extra safety net aboard trains. Its use was mandated after the 1995 Ragnarfjord Train Crash, in which 30 people died because a driver passed a signal at danger after stopping within the safety overlap at a station platform (the signal head was not visible from the cab). | |||
The DRA functions as a kill switch for traction on the train. It is a two-position switch, on and off. When the DRA is set, traction power is disconnected for the train. Railway regulations stipulate that the DRA must be set when shutting a train off, entering or exiting the cab, when the train has stopped for a signal at danger. The DRA may only be turned off when the train has authority to proceed (i.e. the signal clears), the driver has authority to turn on the train, or when the driver has been granted authority to pass a signal at danger by a shunting signal or by radio orders from dispatch. | |||
== Signage == | |||
{| class="wikitable" | |||
|- | |||
! Sign !! Meaning | |||
|- | |||
| [[File:SLgoyanes.png|55px]] || Speed Limit; Applies to trains not using AVK. | |||
|- | |||
| [[File:JunctionSLgoyanes.png|55px]] || Junction Speed Limit; applies in the diverging route indicated and for trains not using AVK. | |||
|- | |||
| [[File:TempSLgoyanes.png|55px]] || Temporary Emergency Speed Limit; applies to all trains. | |||
|- | |||
| [[File:EndTempSLgoyanes.png|55px]] || End Temporary Emergency Speed Limit; applies to all trains. | |||
|- | |||
| [[File:Raisepanto.png|55px]] || Raise Pantograph; The train must raise the pantograph and retract contact shoes. | |||
|- | |||
| [[File:Lowerpanto.png|55px]] || Lower Pantograph; The train must lower the pantograph and deploy contact shoes. | |||
|- | |||
| [[File:Noraisepanto.png|55px]] || Do Not Raise Pantograph; Despite the presence of overhead lines, do not raise the pantographs. | |||
|- | |||
| [[File:Currentchange.png|55px]] || Change In Current; The exact point where the change in current collection happens. | |||
|- | |||
| [[File:Neutral500.png|55px]] || Neutral Zone Advance Warning; There is a neutral zone in specified distance (meters). | |||
|- | |||
| [[File:Longneutral.png|55px]] || Long Neutral Zone Warning; The neutral zone ahead is of considerable length. | |||
|- | |||
| [[File:Openbreakers.png|55px]] || Open Breakers; By this point circuit breakers must be open. | |||
|- | |||
| [[File:Close breakers.png|55px]] || Close Breakers; By this point circuit breakers must be closed. | |||
|- | |||
| [[File:Current indicator.png|55px]] || Current Indicator; Indicates the current type being used. | |||
|- | |||
| [[File:End current.png|55px]] || End Current; The current of the specified type is ending. | |||
|- | |||
| [[File:Whistle board.png|55px]] || Whistle Board; The train must sound its horn or whistle when passing the sign. | |||
|- | |||
| [[File:Tunnel vents.png|55px]] || Close Air Vents; Reminder to the driver that a tunnel is approaching and they must close the air vents to avoid a pressure difference. | |||
|- | |||
| [[File:Train stop all.png|55px]] || Train All Stop; All trains, regardless of length or type, must stop at this sign. | |||
|- | |||
| [[File:HHT Stop.png|55px]] || HHT Train Stop; HHT Trains must stop at the sign. The number indicates the number of trainsets that it applies to. | |||
|- | |||
| [[File:Type stop.png|55px]] || Train Type Stop; Trains of the specified type(s) must stop at the sign. | |||
|- | |||
| [[File:Car stop.png|55px]] || Train Car Stop; Trains of the car quantity specified must stop at the sign. | |||
|- | |||
| [[File:Avk.png|55px]] || AVK Begin; The track ahead is equipped with AVK, the system should exit standby mode. | |||
|- | |||
| [[File:End ask.png|55px]] || End AVK; The track ahead is no longer equipped with AVK, drivers are instructed to set the AVK to standby mode. | |||
|- | |||
| [[File:Override ATS.png|55px]] || Override ATS; The ATS transmitter is not aligned for the operating direction. Drivers have permission to override the signal. | |||
|} |
Revision as of 02:55, 19 March 2020
This article is incomplete because it is pending further input from participants, or it is a work-in-progress by one author. Please comment on this article's talk page to share your input, comments and questions. Note: To contribute to this article, you may need to seek help from the author(s) of this page. |
This article is in work in progress. Any information here may not be final as changes are often made to make way for improvements or expansion of lore-wise information about Goyanes. Please do not edit anything here without the consent of the article's creator. The article's creator is Goyanes (alternate: 20agoyanes). |
Railway signals in Goyanes evolved from electro-mechanical semaphores that changed position to indicate track block status. Before then though, railways employed “track officers” to manage sections of track using hand gestures, line-of-sight techniques, and physical tokens that had to be passed from train to officer and vice versa. This was wildly inefficient, and as the railways grew, technologies were developed to reduce collisions and improve railway safety. Starting with the Grand Trunk Railway and spreading quickly around the nation, electric track circuits that controlled semaphore signals began to take hold. The process started in the 1870s, but by the 1890s, Goyanes’ railway network was fully electronically signaled.
Modern signals in Goyanes use color-light technology, supplemented primarily by the Automatic Train Control (Automatisk Vagenkontroll - AVK) system.
Primary Color Light Signals
Signals in Goyanes use anywhere between two and six aspects. The color aspects are designed to be used in conjunction with the AVK system, however they can function independently of each other, i.e. signals without AVK can govern speed restrictions and AVK without signals operates just fine. AVK operates semi-independently of color signals on HHT lines, and on many secondary lines signals operate independently of AVK.
The primary types of signals in Goyanes are organized into two types: main signals (hovedsignalen) and distant signals (vørsignalen). Depending on the distance between track blocks, a main signal and a distant signal may be combined, however they can and often are separated.
Because in the Goyanean system more green lights means a more restrictive condition, it is not fail-safe and lamp proving circuits are used to ensure safe operating conditions.
Speed limits imposed by the color-lights only apply to trains without AVK equipment. Trains without AVK equipment follow the speed restrictions made by the signal or by posted signs beside the track. Trains with AVK equipment follow the speed directions of the AVK system, but use the color lights to determine the status of the track ahead.
Main Signal (Hovedsignalen) Aspects
Distant Signal (Vørsignalen) Aspects
Freestanding distant signals as shown below are used when the next main signal is more than 3000 meters away. In such cases, the distant signal will be located at least 800 meters before the main signal it protects.
Shunting/Dwarf Signals
Shunting signals, also known as “dwarf signals” (kleinesignalen), are used for shunting purposes in yards, as well as for allowing permittivity of signals at danger such as at entrances to train station platforms to allow shunting or coupling of trains. They are smaller in size, and use only white aspect colors. They may be placed on top of a half-height post, or placed at the same height as the roadbed.
There are also types of dwarf signals, called "Main Dwarf signals" (Hovedkleinsignalen) used as stand-ins for home signals in stations with a lot of shunting operations or where there are a lot of switches that need protection. In addition to the dwarf signal aspects given below, these signals also have a red light and may have two green ones (one for Caution 50, the other for Proceed 100).
Railroad Crossing Status (RCS) Signals
RCS signals (Vagersignalen or VS) are used to indicate to the driver the status of a railroad crossing ahead on the line. Various factors affect the aspect displayed. The most simple kinds simply confer if the gates are closed and locked, but the most advanced types rely on sensors that can detect if vehicles are stalled on the crossing, in addition to detecting whether or not they have been locked. There are two types of RCS signals, just like color-lights, they are Main Signals and Distant Signals. Main RCS signals are identified by a “V” sign under the bulbs. Distant RCS signals are identified by their shape and unique bulb layout.
A related signal called a Bridge Status Signal (Bryggesignalen or BS) uses the same signalheads and aspects, except the main BSS signals have a "B" signpost under the signal head, similar to how main RCS signals have a "V" signal on them.
Main RCS Signals (Hovedvagersignalen/HVS)
Distant RCS Signals (Vørvagersignalen/VVS)
AVK System
The AVK system was invented in 1922 after a Ministry of Transportation commission ruled that the consolidated four railways (Grand Trunk RR, Hysende-Osanhalt-Kongsland RR, The Hirendag Road, Nordstrom Seaboard RR) must install an automatic train stop technology on all trains if they wish to run above 100 km/h. The four railways convened to develop the technology, which was first tested in 1923. They came to the conclusion that not only could they stop the train, they could govern speeds using the cab displays. The way it functioned was by using track currents at either 100 Hz or 91.6 Hz (to avoid electrical interference on 3rd rail lines) to convey pulsating codes to a receiver mounted on the front of the train. The original AVK system used 4 codes, resulting in four basic speeds. They were “posted track speed,” 70 km/h, 50 km/h, and 30 km/h. This first edition was known as AVK-1, and was installed around the country to comply with the new regulations. The AVK system was updated with more codes to remove posted track speeds, and convey all speed information electronically, as well as integrating adaptive speed control into the mix. These iterations were known as AVK-2 and AVK-3.
How modern AVK (AVK-2, -3, -4H, -5H, and -6H) regulates the train is as follows: when the onboard computer receives the track code, the monitor inside the cab will show the new speed readout. On older systems, it would illuminate a bulb corresponding to the readout, on later systems it appears on a digital display. The computer, upon receiving the code, checks the train's speed against the new speed. If the speed is in violation, a warning tone sounds, and initiates a grace period. If braking does not commence in the grace period, the train applies a penalty brake automatically to bring the train into compliance. If the overspeed persists, the emergency brakes are applied. In this regards, AVK is an Automatic Train Control (ATC) system.
In contrast, on AVK-1, there was no speed control, rather it was an advanced form of automatic train stop. If there was a change in restriction, whether positive or negative, the AVK would sound a tone, and if the driver did not acknowledge in a certain timeframe, the emergency brakes were applied.
In the 1960s as the Høyhastikettog (HHT) high-speed trains were being developed, a new AVK generation was devised to create common functionality and safety. This was known as AVK-4H, the H standing for HHT. The system relies on overlay pulse codes at 250 Hz current, which augment the existing 100/91.6 Hz codes to create even more code availability. AVK-4H was installed on most lines and trains by the 1970s.
In 1985, with the widespread adoption of digital computing, AVK-5H was introduced. AVK-5H uses computer stations both lineside and aboard the train to take into account more factors such as braking gradients, train set performance, track geometry, and more to more accurately adjust speeds for trains. In addition AVK-5H and -4H pulse codes remained the same, it was more an upgrade to the computing infrastructure both on the train and lineside.
In recent years, AVK-6H has been developed for use on the HHT system. As speeds increased to 360 km/h, new pulse codes were developed in both the 100/91.6 Hz range and in the 250 Hz range to allow even higher speeds. So far, AVK-6H is only installed on HHT trains capable of >320 km/h and on tracks capable of such speeds. It has full backwards compatibility with -5H to ensure interoperability.
Currently, AVK-4H, -5H and -6H are the most common systems of AVK in use, however usage of -4H is limited to conventional lines, while -5H and -6H are found on high-speed lines, and several dedicated lines. It is installed on most passenger trains in the GJ system, but many freight trains do not have it, and instead rely on the color-light signal aspects for speed regulation.
AVK is failsafe at all generations, as the absence of a pulse code gives a 30 km/h speed limit readout. On lines without AVK, the system can be overridden. The system remains on in a standby state though, and at the first detection of new code, will activate again. Track codes that exceed a train's design speed are nulled out to the highest possible speed for the train by the onboard AVK reciever to ensure safe operation.
AVK Pulse Codes
100/96.1 Hz code | 250 Hz code | Cab Signal Speed | Notes |
---|---|---|---|
0 | 0 | 30 km/h | Original AVK Code. Failsafe State. |
75 | 0 | 50 km/h | Original AVK Code. |
75 | 75 | 70 km/h | Original AVK Code. Remapped starting with AVK-4H. |
96 | 0 | 100 km/h | Original AVK Code, "Posted Speed." Valued at 100 with AVK-2. |
96 | 96 | 130 km/h | Introduced on AVK-2, Remapped with AVK-4H. |
120 | 0 | 160 km/h | Introduced on AVK-2, Remapped with AVK-4H. |
120 | 120 | 200 km/h | Introduced on AVK-3, Remapped with AVK-4H. |
180 | 0 | 240 km/h | Introduced on AVK-4H. |
180 | 180 | 270 km/h | Introduced on AVK-4H. |
270 | 0 | 280 | Introduced on AVK-5H. |
270 | 270 | 300 km/h | Introduced on AVK-5H |
420 | 0 | 320 km/h | Introduced on AVK-6H |
420 | 420 | 360 km/h | Introduced on AVK-6H. |
Automatic Train Stop (ATS)
Automatic Train Stop (Automatisk Togstanna/ATS) is a system that governs color-light signals that are in danger. The current ATS system (ATS-M) was invented at the same time as AVK-4H to protect lines that would use only the normal signal system. Previous ATS systems relied on mechanical infrastructure, such as tripcocks opening brake valves when a signal was passed at danger. Such systems still exist on select railways, such as the Gojannesstad U-Baner, among others. However, on the GJ network, the ATS-M system is operational. It functions on a permanent magnet placed at the center of the track at the end of the safety overlap, several meters past the signal, with an electromagnet placed immediately afterwards in the direction of travel (placed on both sides in omnidirectional lines). When the signal is at danger, the electromagnet shuts off. As the train passes over the magnet, a sensor is tripped by the permanent magnet, and a grace period of about 2 seconds activates. After the expiration, the ATS system sounds a warning alarm, shuts off power and activates the emergency brake.
However, when the signal is clear, the electromagnet turns on (a failsafe, if power is cut to the electromagnet the train is stopped). When the train passes over the permanent magnet, the grace period activates, however the electromagnet untrips the sensor on the train, switching off the ATS system, and sounding a chime in the cab. This allows for positive feedback to remind the driver they have passed a clear or caution signal, and are OK.
The ATS-M system may be overridden (in case of a shunting signal allowing access) by holding down the override button as the train passes over the magnet. Mechanical ATS systems such as on the U-Baner cannot be overridden except by dispatch due to the nature of the system.
Driver Reminding Apparatus (DRA)
The DRA (Førermann Påminnelsemasjin/FPM) is a memory device used as an extra safety net aboard trains. Its use was mandated after the 1995 Ragnarfjord Train Crash, in which 30 people died because a driver passed a signal at danger after stopping within the safety overlap at a station platform (the signal head was not visible from the cab).
The DRA functions as a kill switch for traction on the train. It is a two-position switch, on and off. When the DRA is set, traction power is disconnected for the train. Railway regulations stipulate that the DRA must be set when shutting a train off, entering or exiting the cab, when the train has stopped for a signal at danger. The DRA may only be turned off when the train has authority to proceed (i.e. the signal clears), the driver has authority to turn on the train, or when the driver has been granted authority to pass a signal at danger by a shunting signal or by radio orders from dispatch.